Lesson objective
Write a register entry that states what one automation may do, on which systems, under whose approval and with what stop, clearly enough for a covering manager to enforce it.
Plain-language explanation
Why this matters now
An authority that lives in a settings screen is not an authority. It is a configuration, and configurations change during upgrades, during staff turnover, and during the week the vendor "improves the defaults". A practice that cannot say in writing what each automation may do cannot supervise it, cannot brief a covering manager, cannot answer a patient complaint about it, and cannot investigate it when something goes wrong.
Professional guidance (NIST AI RMF 1.0, NIST AI 100-1, released 26 January 2023; voluntary): the Core has four functions, GOVERN, MAP, MEASURE and MANAGE, and GOVERN "applies to all stages" of AI risk management. Appendix C states that human roles in decision making and oversight "need to be clearly defined and differentiated", and that human-AI configurations span "from fully autonomous to fully manual". The register is how a practice writes that configuration down. NIST binds nobody here, there is no certification to it, and as of 2026-09-15 the framework is being revised under the White House AI Action Plan.
Professional guidance (CISA and partners, 1 May 2026; voluntary): among the risks named in CISA's announcement are privilege creep and obscure event records. A register is the countermeasure to both: it is the document against which today's permissions are compared, and the place that says what should have been logged.
AI Coalition Network recommendation (verified 2026-09-15): no recorded federal rule, state medical board rule or payer policy requires a practice to keep a record of its AI use, and none sets a retention period for one. Every element below is this programme's recommendation, reasoned from ordinary supervision and documentation practice. Do not tell a practice that a rule requires this register, because no recorded rule does.
A question to sit with
If your practice manager were out for three weeks and a locum manager had only this register, could they tell whether an automation had exceeded its authority, and could they stop it before lunchtime?
What goes wrong
The register describes the product, not the authority. Two paragraphs of vendor copy about what the platform can do, and nothing about what this practice permits.
No named owner, or a department named instead of a person. "Front office" cannot approve anything, cannot be asked a question and cannot be found on a Tuesday.
No stop. The entry says what the automation does and nothing about how to make it stop, who may do that without escalating, and what the practice does in the meantime.
No systems list. "The EHR" hides the difference between reading a document queue and writing to a chart.
It is written once. The automation is upgraded in March, gains a new capability in June, and the register still describes February.
Every entry is identical. A register whose entries were copied from one another says the practice never thought about any single automation.
The practical answer
Write one entry per automation per use. The same platform doing two jobs gets two entries, because the authority, the approver and the stop differ.
AI Coalition Network recommendation: fourteen fields per entry.
| # | Field | What it must say |
|---|---|---|
| 1 | Name and version | What staff call it, the vendor and product, the version or release in use, and the date checked |
| 2 | Purpose, in one sentence | The job, phrased so a covering manager could recognise a step outside it |
| 3 | Authority level | 1, 2 or 3 from Lesson 1, and the reason this is the lowest level that does the job |
| 4 | Trigger | The event that starts it, and whether it also runs on a schedule |
| 5 | Systems and data | Every system named individually, each marked read or write, with the records, fields and date range it may reach |
| 6 | Functions | Every function exposed to it, and the functions deliberately withheld |
| 7 | Volume limits | Items per run, runs per day, and what happens when a limit is hit |
| 8 | Outward acts | Each outward act it may prepare, the named approving role, and whether that role must be a licensed clinician |
| 9 | Never | The acts this automation must never take, drawn from the practice's never list |
| 10 | Escalation | The conditions under which it stops and hands off, and the named role that receives the hand-off |
| 11 | Stop | How to stop it, who may do that without asking anyone, how long that takes, and what work moves to manual meanwhile |
| 12 | Logging | What each action records, and where the log can be read |
| 13 | Owners | The automation owner, the output owner for each kind of output, and the security official |
| 14 | Review | The date last reviewed, the date next due, and what would force an early review |
Field 11 deserves emphasis. In a practice, the person who first notices an automation misbehaving is usually a front-desk staff member or a medical assistant at the busiest hour of the day. If stopping it requires finding the operations lead, who must email the vendor, the automation runs for the rest of the afternoon. Name at least two people who may stop it on their own authority, and make sure one of them is normally in the building.
State the never list in the entry, not only in a policy. Lesson 4 gives the practice-wide list. Each entry repeats the items that could plausibly be reached from this automation's position, because that is what a covering manager reads.
Tie the entry to a real log. Field 12 is not decoration. An entry claiming a stop that cannot be evidenced, or an approval nobody can reconstruct, will not survive a complaint. Module 11 specifies the log.
Review on a date, and on events. An AI Coalition Network recommendation is to review every entry at least annually and always after: a vendor release note that mentions new autonomy or new integrations; a change of automation owner or output owner; any incident involving the automation; any change to the practice's systems it reads; and any new state or federal requirement the practice identifies. Record who reviewed and what changed, so that the entry ages visibly rather than silently.
Keep the register where staff already look. A register in a compliance folder nobody opens is a document written for an auditor. Put it, or a one-page summary of it, where the work happens: pinned in the operations handbook, on the intranet page the front desk uses, in the onboarding pack.
Remember this
- An authority that exists only in a settings screen is a configuration, not a decision; write it down per automation and per use.
- Fourteen fields, of which the stop and the escalation are the ones a covering manager needs most.
- Name at least two people who may stop the automation without asking, and keep one of them in the building.
- NIST says human roles in oversight need to be clearly defined and differentiated; the register is where a practice does that, voluntarily.
- No recorded rule requires this register or sets a retention period for it; present it as this programme's recommendation and check state record-retention rules.
Medical practice example
Cedar Hollow Family Medicine keeps a register with eleven entries. The one that earns its keep is for "Eligibility Prefill", an automation that runs each evening against the next day's schedule, checks coverage with the clearinghouse, and stages any mismatch for the registration team. Two months after it goes live, a payer changes a plan identifier format. The automation begins flagging roughly a third of next-day patients as coverage mismatches. The first person to notice is Tomás Vilar, a registration clerk who arrives at seven and finds sixty-one flags where he normally sees six. Under the practice's old habits Tomás would have worked the flags, calling patients to ask about insurance the practice already had on file. Instead he opens the register entry, which is two clicks from the front-desk intranet page. Field 10 says the automation is meant to stop and report if mismatches exceed 15 per cent of the day's schedule, and it did not. Field 11 names him, by role, as one of two people who may disable the nightly job without asking, says it takes about three minutes through the scheduling module, and says that registration reverts to checking eligibility at check-in, using the printed day sheet. Field 13 names the operations lead as automation owner. Tomás disables the job at 7.12 am, prints the day sheet, and messages the operations lead, who confirms with the clearinghouse by mid-morning that the plan identifier format changed and that the escalation threshold had been written against a field the vendor renamed in release 4.2. The practice records the incident, fixes the threshold, re-tests against a fictional day's schedule before re-enabling, and adds a line to field 14 requiring an early review after any vendor release note mentioning field changes. No patient was called about insurance they already had, and the register entry, not anyone's memory, is what made the difference at 7.12 in the morning.
Responsible-use warning
Do not write a register entry that describes what the product can do. The entry exists to say what this practice permits, which is always narrower. The two failures that make an entry useless in the moment are an owner recorded as a department rather than a person, and a stop procedure that requires someone who is not in the building. Both look harmless on the page and both fail on the morning they are needed, when a front-desk clerk is the only person who has noticed anything is wrong.
Human-review requirement
The automation owner drafts the entry. The output owner for each kind of output confirms the approval routes are the ones they would actually use, and that anything clinical routes to a licensed clinician. The security official checks that the systems, functions and limits in fields 5 to 7 match what is really granted rather than what was requested. The practice owner approves the register as a whole and the schedule for reviewing it. Every review is dated and signed, and what changed is recorded next to who changed it.
Practical exercise
Work with a fictional practice, or your own with no patient data and no real credentials.
- Choose one automation your practice runs or is considering, and write its register entry using all fourteen fields from the lesson.
- In field 2, write the purpose so that a manager covering for three weeks could recognise a step outside it. Test the sentence on a colleague who does not work in that area.
- In field 5, name each system separately and mark read or write. Do not write "the EHR"; write the module, the records and the fields.
- In field 6, list the functions withheld as carefully as those granted, and say who could grant a withheld one and how that would be recorded.
- In field 8, name each outward act it may prepare and the approving role, and mark which of those roles must be held by a licensed clinician.
- In field 11, name two people by role who may stop the automation without asking anyone, state how long stopping takes, and describe what work moves to manual in the meantime.
- Write field 10 so that the escalation threshold is a number, not a judgement, and say which report would show whether the threshold has been breached.
- Set the review date in field 14 and list three events that would force an earlier review.
- Give the finished entry to someone outside that department and ask them to answer two questions from it alone: may this automation send anything to a patient, and how would I stop it this morning? Note every place they had to guess.
- Fix each of those places, then write one sentence on where the register will live so that a clerk at seven in the morning can find it.
Knowledge check
-
Why does the same platform doing two different jobs need two register entries?
Answer guidance: Because authority is chosen per use. The two jobs will differ in the systems and fields they reach, the functions they need, the approving role, the never items that apply and the escalation threshold, so one entry would describe neither accurately.
-
What must the stop field say, and why are two named people recommended?
Answer guidance: It must say how to stop the automation, who may do so without asking anyone, how long that takes, and what work moves to manual meanwhile. Two people are named, with one normally in the building, because the person who first notices trouble is usually front-line staff at the busiest hour.
-
What does NIST AI RMF 1.0 say about human oversight roles, and does it bind a practice?
Answer guidance: Appendix C states that human roles in decision making and oversight need to be clearly defined and differentiated, and that configurations range from fully autonomous to fully manual. The framework is voluntary, binds no practice or physician, and has no certification.
-
What may a practice say about how long it must keep register entries and automation logs?
Answer guidance: It may say that no source recorded in this programme sets a period, that this programme recommends keeping superseded entries alongside other operational compliance documentation, and that the practice should check the state record-retention rules that apply to it. It may not say a rule fixes a period.
Sources and further reading
- National Institute of Standards and Technology — Artificial Intelligence Risk Management Framework (AI RMF 1.0), NIST AI 100-1 (2023-01-26). Accessed 2026-09-15.
- Cybersecurity and Infrastructure Security Agency (CISA), Australian Signals Directorate's Australian Cyber Security Centre, and U.S. and international partners — Careful Adoption of Agentic Artificial Intelligence (AI) Services (2026-05-01). Accessed 2026-09-15.
- National Institute of Standards and Technology — Artificial Intelligence Risk Management Framework: Generative Artificial Intelligence Profile, NIST AI 600-1 (2024-07-26). Accessed 2026-09-15.
- AI Coalition Network — Certification Educational Standard: Human Review of AI-Assisted Professional Work. Accessed 2026-09-15.